Project Description
The EF series control devices are normally installed as external operators for
enclosures EJB, EJC and GUB used in the industrial plants, with potential
hazardous atmospheres of gases and combustible dusts, and therefore
classified as Zone 1 – 2 – 21 – 22.
Model | EJBX series enclosures series |
Manufacturer | Nuova ASP |
Made In | ![]() |
Product Code | 10001 |
SPECIFICATIONS
Table scrolling horizontally
Section Tilte 1 | |
Type of protection | for ambient temperature from -60°C up to +40°C per temperatura ambiente da -60°C a +40°C II 2 GD Ex d IIB+H2 T6 – tD A21 T85°C IP 66 II 2 GD Ex d [iA/ib] IIB+H2 T6 – tD A21 T85°C IP 66 for ambient temperature from -20°C up to +80°C per temperatura ambiente da -20°C a +80°C II 2 GD Ex d IIB+H2 T5 – tD A21 T100°C IP 66 II 2 GD Ex d [ia/ib] IIB+H2 T5 – tD A21 T100°C IP 66 for ambient temperature from -20°C up to +130°C per temperatura ambiente da -20°C a +130°C II 2 GD Ex d IIB+H2 T3 – tD A21 T150°C IP 66 II 2 GD Ex d [ia/ib] IIB+H2 T3 – tD A21 T150°C IP 66for ambient temperature from -60°C up to +40°C per temperatura ambiente da -60°C a +40°C II 2 GD Ex d IIB+H2 T6 ÷ T3 – tD A21 T85°C ÷ T150°C IP 66 for ambient temperature from -20°C up to +80°C per temperatura ambiente da -20°C a +80°C II 2 GD Ex d IIB+H2 T5 ÷ T3 – tD A21 T100°C ÷ T150°C IP 66 for ambient temperature from -20°C up to +130°C per temperatura ambiente da -20°C a +130°C II 2 GD Ex d IIB+H2 T3 – tD A21 T150°C IP 66for ambient temperature from -60°C up to +40°C per temperatura ambiente da -60°C a +40°C II 2 GD Ex d IIB+H2 T6 ÷ T3 – tD A21 T85°C ÷ T150°C IP 66 II 2 GD Ex d [ia] IIB+H2 T6 ÷ T3 – tD A21 T85°C ÷ T150°C IP 66 II 2 GD Ex d [ib] IIB+H2 T6 ÷ T3 – tD A21 T85°C ÷ T150°C IP 66 for ambient temperature from -20°C up to +80°C per temperatura ambiente da -20°C a +80°C II 2 GD Ex d IIB+H2 T5 ÷ T3 – tD A21 T100°C ÷ T150°C IP 66 II 2 GD Ex d [ia] IIB+H2 T5 ÷ T3 – tD A21 T100°C ÷ T150°C IP 66 II 2 GD Ex d [ib] IIB+H2 T5 ÷ T3 – tD A21 T100°C ÷ T150°C IP 66 for ambient temperature from -20°C up to +130°C per temperatura ambiente da -20°C a +130°C II 2 GD Ex d IIB+H2 T3 – tD A21 T150°C IP 66 II 2 GD Ex d [ia] IIB+H2 T3 – tD A21 T150°C IP 66 II 2 GD Ex d [ib] IIB+H2 T3 – tD A21 T150°C IP 66 |
Conformity | DIRETTIVA 94/9/CE – ATEX |
Reference rules | EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1; EN 60529 |
Conformity certificate | BKI 06 ATEX 0050 |
Degree of protection | IP 66 |
Ambient temperature use | from -60°C up to +130°C as per mode of protection |
Suitable for Zone | 1 – 2 (Gas) 21 – 22 (Dust) |
Table scrolling horizontally
FEATURES
DOCUMENTS
Title | Type | Volume |
EJBX series enclosures | 312 KB |